FIP IT · Network Infrastructure

Fibre Connectivity Map — Distribution Plan

OFC MM cable Building B server room to Buildings A, C and D, the Security Room, MR Office and Technician Room
Download PDF

Patch panels — Building B server room

Cable layout — Building B server room to field locations

c = fibre cores · c2c = core-to-core splice · solid line = cable from the server room or a continuing cable · dashed line = onward splice from the C-GF patch panel

Building B — server room end

Splice detail drawings — Building B server room

Drawn from the patch panel port tables: each cable's cores are shown spliced to pigtails on the listed ports, and spare ports are not spliced. Confirm the connector type and any wound cores at Building B and update this block if they differ.

Field locations end

Splice detail drawings — field locations

Each line is one fibre core, 2 cores per pair, in the standard 12-colour fibre code (repeating after core 12). The dashed box is the fusion splice tray; each small sleeve is one fused core. Wound spare cores are not spliced.

Cable routes & splice details

Patch Panel 01 → Building C

1 cable:
  • 24-core OFC to Building C GF
  • Ports 1–4C-GF: 4 pairs spliced to SC connectors. Local termination.
  • Other coresCore-to-core spliced inside the C-GF patch panel: 3 pairs onto MM OFC to Building C First Floor, and 3 pairs onward to Building D. Remaining cores wound inside.

Patch Panel 02 → Building A

2 cables:
  • 24-core MM OFC to Building A GF cabinet
  • 12-core OFC to Building A FF
  • 24-core cableA-GF: 8 cores (4 pairs) already spliced to SC connectors. Local termination in the cabinet patch panel. Remaining cores wound inside.
  • 12-core cableA-FF: 8 cores (4 pairs) already spliced in the Building A First Floor patch panel. Remaining cores wound inside.

Patch Panel 03 → Security, MR Office, Technician

2 cables:
  • 12-core MM OFC to Security Room patch panel
  • 12-core MM OFC to Technician Room
  • Security cableSecurity Room: 6 cores (3 pairs) spliced to LC connectors. Local termination.
  • Other coresCore-to-core spliced inside the Security Room patch panel: 6 cores (3 pairs) onto a 12-core MM OFC to MR Office, spliced locally at the end.
  • Technician Room:6 cores (3 pairs) spliced to LC connectors. Local termination.

Location colour code